| Online UPS TTX Series | ||||||||||
| Technical Specifications | ||||||||||
| Model | TTX10 | TTX15 | TTX20 | TTX30 | TTX40 | TTX60 | TTX80 | TTX100 | TTX120 | |
| Capacity | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | |
| Power | 8KW | 12KW | 16KW | 24KW | 32KW | 48KW | 64KW | 80KW | 96KW | |
| Power Factor | 0.8 | |||||||||
| Input | Phase | 3 phase 4 wire and ground | ||||||||
| Voltage Range | +/-20% | |||||||||
| Frequency Range | 45 – 65Hz | |||||||||
| Rectifier | 3 phase 6 pulses | |||||||||
| Output | Phase | 3 phase 4 wire and ground | ||||||||
| Wave form | Sine wave | |||||||||
| Crest Factor | 3:01 | |||||||||
| Rated voltage | 380/400/415V optional | |||||||||
| Phase voltage setting | 200 - 244VAC (control panel ) | |||||||||
| Transient response | +/-5%, 10ms | |||||||||
| Frequency | 50 / 60 Hz | |||||||||
| Frequency stability | + / - 0.05% | |||||||||
| Range of phase lock | With synchronization: +/-0.05% | |||||||||
| Without synchronization: + /- 2% (settable +/-1% on the control panel) | ||||||||||
| Total harmonic distortion | 3% ( linear load) | |||||||||
| Short circuit current | Short current for 0.1s (200% current) | |||||||||
| Overload capacity | 110% /125% /150% rated current 300 min/ 10min /1min | |||||||||
| Battery | Battery | Maintenance free lead-acid cell | ||||||||
| DC Voltage | 384VDC | |||||||||
| Bypass | Type | Static state + manual maintenance bypass | ||||||||
| Input Phase | 3 phase 4 wire and ground | |||||||||
| Input voltage range | 15% - 25% (the front control panel selectable) | |||||||||
| Input frequency range | +/-1% ~ +/- 5% the front control panel selectable | |||||||||
| Transfer time | Inverter / bypass transfer swiTTXh time(Overload): 0ms inverter / bypass transfer swiTTXh time (fault inverter) 1ms | |||||||||
| Overload capacity (10 min) | 170% | 180% | 170% | 170% | 170% | 140% | 130% | 125% | 125% | |
| Remote signaling | Dry contact (battery low, battery discharging, bypass/ fault); output 12Vdc/80mA | |||||||||
| Remote control | EPO and bypass | |||||||||
| Communication interface | RS232 ( SNMP , modem optional ) | |||||||||
| Running temperature | 0-40 degree Celsius | |||||||||
| Relative Humidity | Less than 95% (without condensing) | |||||||||
| Altitude | 1000m output nominal power (with increase of 100m, it will reduce output of 1%) max 4000m | |||||||||
| Noise at 1 M | less than 60 dB | |||||||||
| Inverter Efficiency | 92% | |||||||||
| Degree of protection | IP20 | |||||||||
| Applicable Standards | EN50091-1-EMC EN50091-2liv.A | |||||||||
| Optional | Isolating transformer | |||||||||
| Harmonic wave suppression filter | ||||||||||
| Parallel modules can be up to six | ||||||||||
| Net weight (Kg) | 210 | 230 | 230 | 282 | 330 | 450 | 555 | 650 | 750 | |
| Gross weight (Kg) | 260 | 280 | 280 | 332 | 380 | 505 | 600 | 700 | 800 | |
| Packing (W×D×H) | 650×850×1340 | 950×890×1620 | 1070×740×1400 | |||||||